STOE IPDS II

State of the art diffractometer with extremely sensitive and reliable imaging plate technology

Unparalleled reliability, built to serve all scientific needs: e.g. small molecules, proteins, electron density measurements. Full accessibility of the sample environment for easy adaptation of high and low temperature attachements as well as high pressure cells.

 

Features

  • One single instrument for small molecules & proteins
  • Very high dynamic range (16 bits)
  • Extremly low background (no dark current)
  • Perfect for weak scatterers
  • Reliable intensities of very weak and very strong reflexions within the same frame
  • Long lifetime, low maintenance, low costs of ownership

Accessories

X-ray fibre optics
Goniometer heads
Low- and high-temperature attachments
Download brochure
X-ray fibre optics

On STOE’s Imaging Plate Diffraction Systems IPDS II, IPDS 2T and the STADIVARI with the DECTRIS PILATUS detector the normal pin hole collimator can be exchanged against an X-ray fibre optic. The use of this optic provides a gain in intensity depending on the anode material (eg. factor 2 for Mo Kα, better for Cu Kα), sample dimension (and sample-to-detector distance).

  • In this way the well known accuracy of the data sets can now be obtained in 1/2 of the exposure time with Mo radiation.
  • The data quality stays the same or is even better while no significant raise in the background is observed.
  • No broadening of peak halfwidths could be detected.

The X-ray fibre optic is an effective and inexpensive alternative to a rotating anode at the STOE Imaging Plate Diffraction System IPDS II, IPDS 2T and the StadiVari with the DECTRIS PILATUS detector.

Goniometer heads

STOE provides the suitable goniometer head for each task, whether large, standard or small, lockable x,y,z or fully height adjustable, all STOE goniometer heads are of excellent precision, have the standard IUCR mount and are delivered with the necessary equipment.

Low- and high-temperature attachments

Low Temperature
O.E.M. attachments like the Oxford Cryosystems coolers can easily be mounted on each STOE single crystal diffractometer. The low cost and low maintenance Desktop Cooler (DTC) can be used as well as the traditional Cryostream or the non-liquid nitrogen Cobra.

Heatstream
As non-ambient methods are becoming increasingly popular, STOE provides a powerful high-temperature attachment for its single crystal diffractometers, the HEATSTREAM.

Features

  • Temperature range from RT to 1000 K
  • Temperature accuracy within +/- 1 K – Heating medium N2
  • No limitation in 2Θ, ω or phi
  • Vertical gas flow for optimal sample heating

Specifications

System Specifications
Dimensions (including system cabinet, max.) 1680 x 880 x 2110 mm
Weight (complete system) 390 kg
Max 2θ : 77°
Goniometer ω: 180° | φ : 360°
Detector distance 40 – 200 mm (automatically set)
Minimum d/Å 0.45 Ag Kα, 0.57 Mo Kα
X-ray sources Sealed Tubes: Ag, Mo, Cu | Microfocus sources: Ag, Mo, Cu
DETECTOR SPECIFICATIONS
Diameter Image Plate (active area) 340mm
Intrinsic noise low noise due to absence of darkcurrent
Linear dynamic range > 1:10⁵

Interested?

For any further question please do not hesitate to contact us.

Downloads

Do you need more information about this product?
Ask us
  • This field is for validation purposes and should be left unchanged.